Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/23935
Title: Pemeliharaan Deaerator PLTU PT PLN (Persero) Unit Pelaksana Pembangkitan Belawan
Other Titles: PT PLN (Persero) PLTU Deaerator Maintenance, Belawan Power Plant Implementation Unit
Authors: Sianturi, Simon Andry.S.
metadata.dc.contributor.advisor: Jufrizal
Keywords: PLTU;deaerator;metode deaerasi;pemeliharaan;deaeration method;pemeliharaan
Issue Date: 27-Mar-2024
Publisher: UNIVERSITAS MEDAN AREA
Series/Report no.: NPM;218130075
Abstract: Proses produksi listrik di PLTU PT PLN (Persero) Unit Pelaksana Pembangkitan Belawan tidak lepas dari suplai air pengumpan yang dilakukan oleh Deaerator yang didorong oleh Boiler Feed Pump. Sebelum diubah menjadi uap di Boiler, air pengumpan ini dilakukan proses-proses secara bertahap, seperti proses penghilangan unsur oksigen yang masih terkandung dalam air pengisi. Pada proses di Deaerator terjadi kontak langsung antara pengisi dan uap, oleh karena itu uap akan memisahkan gas dari air pengisi kemudian gas-gas tersebut bergerak dengan cepat ke bagian atas Deaerator dan selanjutnya dibuang ke atmosfer. Fungsi utama dari deaerator yaitu menghilangkan gas-gas non condensable gas dan sekaligus memanaskan air kondensat. Media pemanas yang digunakan adalah uap ekstrasi dari LP Turbine dan Auxiliary Steam Header. Semakin dekat temperatur air kondensat dengan titik didihnya, semakin mudah pula proses pemisahan air dengan gas-gas non condensable lainnya yang terlarut dalam air kondensat. Metode pemurnian yang digunakan pada Deaerator yaitu dengan proses deaerasi. Deaerasi adalah perlakuan terhadap air untuk menghilangkan gas-gas yang larut dalam air. Adapun yang dilakukan pada Deaerator ini adalah pemeliharaan. Temperatur Deaerator sebelum pemeliharaan 170,30C dan setelah pemeliharaan 177,30C. Electrical production process at PLTU PT PLN (Persero) Belawan Power Generation Implementation Unit can not be separated from feed water supply by Deaerator driven by Feed Pump Boiler. Before being converted to steam in the Boiler, the water feeder is gradually processed, such as the process of removing the oxygen element still contained in the fill water. In the process in the Deaerator there is direct contact between the filler and the vapor will separate the gas from the filler water then the gases move qiuckly to the top of the Deaerator and then thrown into the atmosphere. The main function of the Deaerator is to eliminate non-condensable gas gases and simultaneously heat condensate water. Heating medium used is steam extraction from LP Turbine and Auxiliary Steam Header. The closer the condensate water temperature to its boiling point, the more easily the process of spilitting water with other non-condensable gases dissolved in condensate water. The purification method used in Deaerator is by deaeration process. Deaeration is the treatment of water to remove water-soluble gases. The thing done on this Deaerator is maintenance. Deaerator Temperature before maintenance : 170,30C and after maintenance : 177,30C.
Description: 58 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/23935
Appears in Collections:SP - Mechanical Engineering

Files in This Item:
File Description SizeFormat 
218130075 - Simon Andry.S. Sianturi - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography1.66 MBAdobe PDFView/Open
218130075 - Simon Andry.S. Sianturi - Chapter IV.pdf
  Restricted Access
Chapter IV544.04 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.