Title: Evaluasi Perhitungan Tiang Pancang Dari Data Spt Dengan Hasil Pda Test Pada Tangki Air Kapasitas 5.000 Kilo Liter Di Sei Siak Pekan Baru
Other Titles: Evaluation of pile calculations from SPT data with PDA test results on water tanks with a capacity of 5,000 kilo liters in Sei Siak Pekan Baru
Authors: Syahrian
metadata.dc.contributor.advisor: Wulandari, Tika Ermita
Keywords: Foundation bearing capacity;PDA Test;SPT (Standard penetration test);Daya dukung pondasi
Issue Date: 7-Jul-2023
Publisher: Universitas Medan Area
Series/Report no.: NPM;188110100
Abstract: Pondasi adalah bagian dari suatu sistem struktur bawah (sub structure) yang menahan berat sendirinya dan seluruh beban gaya dari struktur atas, kemudian meneruskannya ke lapisan tanah dan batuan yang terletak di bawahnya.. Penelitian ini bertujuan untuk Mengetahui daya dukung pondasi dengan menggunkan metode mayerhoff, Mengetahui efisiensi kelompok tiang pancang menggunkan formula feld. Untuk mengetahui perbandingan hasil analitis yang dilakukan dengan hasil data PDA test serta mengetahui metode mana yang lebih mendekati data lapangan PDA test .. Dari hasil penelitian yang dilakukan penulis menemukan bahwa Hasil perencanaan pondasi tiang pancang setelah dievaluasi dengan PDA test dinyatakan aman karena nilai daya dukung yang dihasilkan dari pengujian PDA test lebih besar dari nilai perencanaan. Dimana daya dukung tiang tunggal berdasarkan data SPT (mayerhoff) pada kedalaman 30 meter sebesar 126,7ton dan dari hasil PDA test sebesar 194 ton, kedalaman pemancangan memungkinkan hanya pada kedalaman 30 meter dantidak perlu sampai pada kedalaman lebih dari 30 meter, Jumlah tiang yang dibutuhkan sebanyak 54 titik lebih sedikit dibandingkan dengan jumlah tiang yang sudah digunakan (dipancang). The foundation is part of a substructure system (sub structure) which supports its own weight and all the force loads from the superstructure, then passes it on to the layers of soil and rock beneath it. This study aims to determine the bearing capacity of the foundation using the Mayerhoff method, to determine the efficiency of pile groups usingformula field. To find out the comparison of the results of the analysis carried out with the results of the dataPDA test as well as knowing which method is closer to field dataPDA test .. From the results of research conducted by the authors found that the results of the pile foundation planning after being evaluated with the PDA test were stated to be safe because the carrying capacity value resulting from the PDA test test was greater than the planning value. Where is the carrying capacity of a single pile based on SPT data(mayerhoff) at a depth of 30 meters is 126.7 tons and from the results of the PDA test of 194 tons, the driving depth is possible only at a depth of 30 meters and does not need to reach a depth of more than 30 meters. used (designed).
Description: 95 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/22671
Appears in Collections:SP - Civil Engineering

Files in This Item:
File Description SizeFormat 
188110100 - Syahrian - Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography2.09 MBAdobe PDFView/Open
188110100 - Syahrian - Chapter IV.pdf
  Restricted Access
Chapter IV270.39 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.