Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/20999
Title: Analisis Perbandingan Gangguan Hubung Singkat Tiga Fasa dan Gangguan Satu Fasa Ketanah Sistem Tenaga Listrik Menggunakan Program Matlab
Other Titles: Comparative Analysis of Short Circuit Faults Three Phase and One Phase to Ground Fault in Power System Using Matlab Program
Authors: Kurniawan, Harry
metadata.dc.contributor.advisor: Harahap, Usman
Keywords: comparison;short circuit calculation;matlab;perbandingan;hubung singkat;tiga fasa
Issue Date: 2015
Publisher: Universitas Medan Area
Series/Report no.: NPM;088120041
Abstract: Penelitian Tugas Akhir ini membahas tentang analisis perbandingan hubung singkat satu fasa ketanah dan tiga fasa pada sistem tenaga listrik yang terdiri dari dua unit generator terhubung dengan tiga buah bus melalui saluran transmisi. Penelitian tugas akhir diawali dengan membentuk diagram reaktansi dari single line diagram sistem tenaga listrik. Dari diagram reaktansi akan dibentuk rangkaian urutan no, urutan positif dan urutan negatif. Kemudian dari diagram urutan tersebut dimodelkan perhitungan gangguan hubung singkat dengan menggunakan bantuan perangkat lunak. Perangkat lunak yang digunakan untuk analisis dalam penelitian ini menggunakan Matlab 7. Basil analisis kemudian diamati untuk membandingkan besaran gangguan hubung singkat Tiga Fasa, dan Satu Fasa Ketanah. Besaran gangguan hubung singkat yang dibandingkan dimaksud untuk mengetahui parameter gangguan terbesar (maksimum) dari ke em pat jenis gangguan tersebut. Basil penelitian menunjukkan arus gangguan tiga fasa lebih besar dibandingkan arus gangguan satu fasa ketanah. Research final discusses the comparative analysis of single phase short circuit to the ground and three phase electric power system consisting of two generator units tehubung with three bus through a transmission line. The study begins with the final form of the single line diagram of reactance diagram of electric power systems. From the diagram of the circuit reactance will be set up zero sequence, positive sequence and negative sequence. Then from the sequence diagram is modeled calculations of short circuit interruption with the help of software. The software used for analysis in this study using Matlab 6.1. The results of the analysis is then observed to compare the magnitude of short circuit interruption Three Phase, and Phase One ground. Magnitude than the short circuit interruption meant to know the parameters of greatest disturbance (maximum) of the four types of the disorder. The results showed a three-phase fault current is greater than a single phase ground fault current.
Description: 45 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/20999
Appears in Collections:SP - Electrical Engineering

Files in This Item:
File Description SizeFormat 
088120041 - Harry Kurniawan Fulltext.pdfCover, Abstract, Chapter I, II, III, V, Bibliography2.25 MBAdobe PDFView/Open
088120041 - Harry Kurniawan Chapter IV.pdf
  Restricted Access
Chapter IV1.23 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.