Please use this identifier to cite or link to this item: https://repositori.uma.ac.id/handle/123456789/17884
Title: Analisis Perpindahan Panas Pada Kondenor Tipe Shell And Tube
Other Titles: Heat Transfer Analysis in Shell And Tube Type Condensers
Authors: Rifaldo, Zulpikar
metadata.dc.contributor.advisor: Ibrahim, Husin
Nasution, Amirsyam
Keywords: Kondensor;Laju Perpindahan Panas;Effektifitas;Condenser;Heat Transfer Rate;Effectiveness
Issue Date: 11-Jan-2022
Publisher: Universitas Medan Area
Series/Report no.: NPM;168130079
Abstract: Alat penukar kalor merupakan suatu alat yang digunakan untuk menukar atau mengubah temperatur fluida dengan mempertukarkan kalornya dengan fluida lain. Salah satu dari alat penukar kalor adalah kondensor tipe permukaan dimana uap terpisah dari air pendingin, uap berada diluar pipa-pipa sedangkan air pendingin berada dalam pipa yang terdapat di PT. SOCIMAS. Pada PT. SOCIMAS, kondensor merupakan bagian sistem pendingin yang utama yang berfungsi untuk mengkondensasikan uap menjadi air dan menjaga efisiensi dan siklus kerja turbin tetap tinggi. Untuk itu laporan tugas akhir ini fokus pada analisis kondensor. Hasil yang didapat dari tugas akhir ini adalah nilai koefisien konveki dalam 4056.6827 W/m2.K dan koefisien konveksi luar sebesar 97414.18 W/m2.K nilai laju perpindahan panas dan effectiveness (ε) pada kondensor PT. SOCIMAS diperoleh laju perpindahan panas sebesar 153.6001264 MW. Sedangkan effectiveness (ε), diperoleh 0.99571 % Hal ini menunjukkan bahwa keadaan kondensor cukup baik, dikarenakan steam dapat menuju kondensor, sehingga laju perpindahan panas dan effektifitas kondensor mampu mengkondensasi steam menjadi cair. A heat exchanger is a device used to exchange or change the temperature of a fluid by exchanging heat with another fluid. One of the heat exchangers is a surface type condenser where the steam is separated from the cooling air, the steam is outside the pipes while the cooling water is in the pipes at PT. SOCIMAS. At PT. SOCIMAS, the condenser is the main part of the cooling system whose function is to condense the steam into air and keep the efficiency and work cycle of the turbine high. For this reason, this final report focuses on condenser analysis. The results obtained from this final project is the value of the coefficient of internal convection is 4056.6827 W/m2.K and the coefficient of external convection is 97414.18 W/m2.K value of heat transfer rate and effectiveness (ε) on the condenser PT. SOCIMAS obtained a heat rate of 153,6001264 MW. While the effectiveness (ε), obtained 0.99571% This indicates that the condition of the condenser is quite good, because steam can be a condenser, so that the heat transfer rate and the effectiveness of the condenser are able to condense steam into liquid.
Description: 41 Halaman
URI: https://repositori.uma.ac.id/handle/123456789/17884
Appears in Collections:SP - Mechanical Engineering

Files in This Item:
File Description SizeFormat 
168130079 - zulpikar Rifaldo - Fulltext.pdfCover, Abstract, Chapter I,II,III,V, Bibliography861.77 kBAdobe PDFView/Open
168130079 - zulpikar Rifaldo - Chapter IV.pdf
  Restricted Access
Chapter IV487.4 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.